<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Advances in Skin, Wound and Tissue Repair</title>
<title_fa>Advances in Skin, Wound and Tissue Repair</title_fa>
<short_title>ASWTR</short_title>
<subject>Medical Sciences</subject>
<web_url>http://icml.ir</web_url>
<journal_hbi_system_id>105</journal_hbi_system_id>
<journal_hbi_system_user>journal105</journal_hbi_system_user>
<journal_id_issn>1735-3319</journal_id_issn>
<journal_id_issn_online></journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/aswtr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی تأثیر نشت نوری و حساسیت بر تابع نقطه گستر دستگاه تصویربرداری فلورسنت جراحی در فانتوم معادل بافت</title_fa>
	<title>Effect of Light Leakage and Sensitivity on Point Spread Function of Intraoperative Fluorescence Imaging System in a Tissue-like Phantom</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&amp;nbsp;&lt;strong&gt;مقدمه: &lt;/strong&gt;تهیه نقشه گره لنفاوی سنتینل در تشخیص سرطان و یافتن روش درمانی بهینه موثر است. نقشه گره لنفاوی سنتینل با استفاده از روش تصویربرداری نوری تهیه می&#8204;شود . مطالعات اخیر نشان می&#8204;دهد که نشت پرتوی منبع تابنده مهمترین عاملی است که در تصاویر اکتسابی نسبت سیگنال به نویز و حساسیت را تحت تاّثیر قرار می&#8204;دهد&#8204;و منجر به عدم تشخیص دقیق گره&#8204;های لنفاوی سنتیل می&#8204;گردد. هدف از این مطالعه ارزیابی تاثیر نشت نوری و حساسیت بر تابع نقطه گستر دستگاه تصویربرداری فلورسنت جراحی در فانتوم معادل بافت می&#8204;باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;روش بررسی: &lt;/strong&gt;در این مطالعه شش چینش اپتیکی مختلف با استفاده از نرم&#8204;افزار زیمکس طراحی و سپس اجرا شد. موقعیت مناسب منبع-آشکارساز با روش اجزای محدود تحت نرم افزار NIRFAST شبیه سازی و بهینه شد. فانتومی با خصوصیات مشابه بافت جهت تصویربرداری ساخته شد. میزان نشت نور تحریکی با استفاده از رابطه نسبت انتقال و مقدار تابع نقطه گستر با محاسبه FWHM بدست آمد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;یافته ها: &lt;/strong&gt;نسبت انتقال برای چینش مرجع و چینش نهایی به ترتیب از 452/0 به 192/0 تغییر کرد ( 0006/0 p&lt; ). مقدار تابع نقطه گستر با استفاده از چینش مرجع 9/49 پیکسل و برای چینش نهایی 1/39 پیکسل بدست آمد (0001/0 P&lt; ). ارزیابی آماری نشان داد که میزان نشت نور تحریکی در چینش نهایی 58% نسبت به چینش مرجع کاهش یافت و مقدار تابع نقطه گستر 22% برای چینش نهایی نسبت به چینش مرجع بهبود داشت.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;div&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;بحث و نتیجه گیری: &lt;/strong&gt;این روش برای کاهش نشت نور تحریکی برای اعتبار بخشی به سیگنال های جمع آوری شده برای تصویربرداری فلورسانس ارائه شده است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Background and Aim: &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;Sentinel lymph node mapping is effective for breast cancer diagnosis and efficient treatment. Sentinel lymph node mapping is performed by using optical imaging. Recent studies indicate that excitation light leakage stranding is the most important factor in images acquired signal to noise ratio, and sensitivity can be affected and does not provide accurate diagnosis for lymph node sentinel. The aim of this project is to assess the impact of light leakage and sensitivity over the surgery fluorescence imaging system point spread function in tissue-like phantom&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Material and Methods:&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;Six different optical were designed and implemented with different combinations of lenses and filters include the laser, achromatic lenses and filters by using Zemax software. Appropriate position source-detector simulated with finite element method by NIRFAST software (Algorithm for numerical model and image reconstruction). Tissue-like phantom were made for imaging. The excitation light leakage was calculated by transmission ratio equation and point-spread function was determined by using &amp;quot;Full width at half maximum&amp;quot; (FWHM). &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Results: &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;The best design consisted of two lenses and two filters (a filter between two lenses and other filters between phantom and objective lens) with a value of 0.192&amp;plusmn;0.002 light leakage (p&lt;0.0006) and 22% improvement in the point spread function than the current designs, consisting of a lens and the filter, in a similar system. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;The method for reducing excitation light leakage is presented for validating collected signals for fluorescence imaging. The researchers can use correction coefficient to obtain accuracy intensity of fluorescence concentration.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>تصویربرداری فلورسنت جراحی, گره لنفاوی سنتینل, نشت نوری, تابع نقطه گستر, نرم افزار NIRFAST, نرم افزار زیمکس</keyword_fa>
	<keyword>Light Leakage, Sensitivity, Intraoperative Fluorescence Imaging System.</keyword>
	<start_page>27</start_page>
	<end_page>34</end_page>
	<web_url>http://icml.ir/browse.php?a_code=A-10-6-149&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابراهیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ebrahimi-m@razi.tums.ac.ir</email>
	<code>1050031947532846004926</code>
	<orcid>1050031947532846004926</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مرجانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حجازی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004927</code>
	<orcid>1050031947532846004927</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حریرچی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004928</code>
	<orcid>1050031947532846004928</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>پروین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزاقوامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004929</code>
	<orcid>1050031947532846004929</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات علوم و تکنولوژی در پزشکی، بیمارستان امام خمینی(ره)، تهران،‌ ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
