<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Advances in Skin, Wound and Tissue Repair</title>
<title_fa>Advances in Skin, Wound and Tissue Repair</title_fa>
<short_title>ASWTR</short_title>
<subject>Medical Sciences</subject>
<web_url>http://icml.ir</web_url>
<journal_hbi_system_id>105</journal_hbi_system_id>
<journal_hbi_system_user>journal105</journal_hbi_system_user>
<journal_id_issn></journal_id_issn>
<journal_id_issn_online>3116-1677</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/aswtr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی تأثیر نگهداری در آب بر چسبندگی کامپوزیت به مینای لیزرشده با Er:YAG</title_fa>
	<title>Effect of water storage on the Bond Strength to lased enamel With Er YAG laser</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;direction: rtl; text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;مطالعۀ حاضر با هدف بررسی اثر نگهداری در آب بر استحکام باند ریزکششی ادهزیوهای Etch and Rinse دو &#8204; مرحله &#8204; ای به مینای درمان &#8204; شده با لیزر Er:YAG طراحی شده &#8204; است.&lt;br&gt;
&lt;strong&gt;روش&#8204;بررسی: &lt;/strong&gt;اسلپ &#8204; های 2 &amp;times;8&amp;times;8 میلی &#8204; متر از انسیزورهای انسانی تهیه شدند و سپس این اسلپ &#8204; ها به &#8204; صورت تصادفی در6 گروه قرار گرفتند. سطح مینای 3 گروه توسط لیزر Er:YAG درمان شدند. پس از آماده &#8204; سازی سطوح مینایی تمام نمونه &#8204; ها با اسید &#8204; فسفریک 37 درصد، نمونۀ کامپوزیتی از Z250 توسط ادهزیو Single Bond 2 به آن &#8204; ها باند شدند سپس نمونه &#8204; ها براساس مدت &#8204; زمان نگهداری در آب در 3 گروه قرار گرفتند: 24 ساعت (فقط جهت تکمیل پلیمریزیشن)، 6 و 12 ماه. استحکام کششی نمونه &#8204; ها در دستگاه universal testing machine با سرعت mm/min 5/0 بررسی و اعداد برحسب مگاپاسکال (و بر اساس متوسط عدد هر نمونۀ حذف &#8204; شده) گزارش شدند. پس از تخمین میانگین Mean و SD ، داده &#8204; ها توسط آزمون two-way ANOVA و آزمون تکمیلی Tukey HSD آنالیز شدند(05/0= &amp;alpha;).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;آنالیز Two-way ANOVA نشان داد که اثر فاکتور اصلی زمان نگهداری در آب از &#8204; نظر آماری معنی &#8204; دار بود(001/0 P &lt; ) ولی اثر لیزر تفاوت معنی &#8204; داری را نشان نداد(05/0 P &gt; ) . اثر متقابل زمان نگهداری در آب و لیزر، تفاوت معنی &#8204; داری را نشان داد( 001/0= P ) . آزمون تکمیلی Tukey HSD نشان داد که بین گروه &#8204; های نگهداری &#8204; شده در آب تفاوت آماری معنی &#8204; داری وجود دارد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری: &lt;/strong&gt;استحکام باند ریز کششی ادهزیو به سطوح مینایی لیزر &#8204; شده و بدون لیزر، تفاوت آماری معنی &#8204; داری نداشتند. با &#8204; این &#8204; حال اثر مدت &#8204; زمان نگهداری در آب، معنی &#8204; دار بود. بدین &#8204; ترتیب با افزایش زمان نگهداری، استحکام باند کاهش می &#8204; یابد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Background and Aim:&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; This study evaluated the influence of storage time on micro- tensile bond strength&lt;span style=&quot;letter-spacing:.9pt&quot;&gt; of &amp;ldquo;two step etch and rinse adhesives&amp;rdquo; to treated enamel&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;letter-spacing:.9pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; with Er;YAG laser.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; Human incisor teeth were sectioned to 8&amp;times;8&amp;times;2 Dimensions beams and randomly divided into 6 groups. Enamel surface of samples from three groups (III, IV, V) were prepared with Er;YAG laser. Single Bond 2 was used to bond a composite rod (Z250) to enamel surfaces. Each group was further divided into three subgroups according to water storage time; 24 hours (only for polymerization completion), 6 and 12 months. Micro-tensile bond strengths were determined under a crosshead speed of 0,5mm/min using a universal testing machine and expressed in MPa. Data was statistically analyzed by ANOVA and Tukay post hoc test.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; Two way ANOVA results showed significant effect of storage time on bond strength (p&lt;0.001) but laser application was not significantly effective. Laser and storage time interaction effects were significantly different (p=0.001). Tukey HSD results demonstrated significant differences between stored groups. The micro-tensile bond strength of adhesives to lased and non lased enamel surfaces does not provide significant differences. However, bond strength was influenced by the storage time, being stronger with decrease of water storage duration.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>ادهزیو2مرحله‌ای, نگهداری در آب, مینا, استحکام باند ریزکششی, لیزر  Er:YAG</keyword_fa>
	<keyword>Two-step Adhesive, Water Storage, Enamel, Micro-tensile Bond Strength, Er,YAG Laser</keyword>
	<start_page>1</start_page>
	<end_page>7</end_page>
	<web_url>http://icml.ir/browse.php?a_code=A-10-6-146&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهشتی‌روی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>@yahoo.com</email>
	<code>1050031947532846004911</code>
	<orcid>1050031947532846004911</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکدۀ دندانپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>شاهین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کسرایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004912</code>
	<orcid>1050031947532846004912</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکدۀ دندانپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خام‌وردی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004913</code>
	<orcid>1050031947532846004913</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکدۀ دندانپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>‌مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مرتضوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004914</code>
	<orcid>1050031947532846004914</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکدۀ دندانپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>محدثه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آذرسینا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Azarsina2012</email>
	<code>1050031947532846004915</code>
	<orcid>1050031947532846004915</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکدۀ دندانپزشکی، دانشگاه علوم پزشکی شهید بهشتی، واحد بین الملل، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
