<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Advances in Skin, Wound and Tissue Repair</title>
<title_fa>Advances in Skin, Wound and Tissue Repair</title_fa>
<short_title>ASWTR</short_title>
<subject>Medical Sciences</subject>
<web_url>http://icml.ir</web_url>
<journal_hbi_system_id>105</journal_hbi_system_id>
<journal_hbi_system_user>journal105</journal_hbi_system_user>
<journal_id_issn>1735-3319</journal_id_issn>
<journal_id_issn_online></journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/aswtr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهینه‌سازی دستگاه سی‌تی‌اسکن لیزری به‌منظور دوزیمتری ژل براساس طراحی جدید اپتیکی</title_fa>
	<title>Optimization of laser CT scanner for gel dosimetry, introducing a new optical design</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;در این مقاله برای بهینه &#8204; سازی اسکنر سی &#8204; تی لیزری که به منظور دوزیمتری ژل معادل بافت به &#8204; کار می&amp;shy;رود، ساختار اپتیکی جدیدی پیشنهاد شده&#8204;&amp;shy;است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;روش&#8204;بررسی: &lt;/strong&gt;روند کار براساس به &#8204; کارگیری یک دیود لیزری به &#8204; عنوان منبع نور و سه چیدمان پیاپی اپتیکی با هدف هدایت بهینۀ پرتوی اپتیکی جهت بازخوانی دقیق ژل معادل بافت مبتلا به تومور بنا شده&amp;shy;است. تا به امروز، روش تصویربرداری تشدید پارامغناطیس ( MRI ) به &#8204; صورت گسترده&amp;shy;ای برای ارزیابی توزیع دوز جذبی در دوزیمتری ژل معادل بافت مورد استفاده بوده&amp;shy;&#8204;است؛ با این&#8204;حال، به&#8204;دلیل مسائل عملیاتی ازقبیل دردسترس بودن، هزینه و تجهیرات و اسکن اپتیکی ژل بارها توسط محققان به &#8204; عنوان یک جایگزین دقیق و کاربردی برای MRI به &#8204; کار گرفته شده&#8204;&amp;shy;است. پتانسیل روش سی &#8204; تی &#8204; اسکن اپتیکی به &#8204; صورت تجربی نیز مورد کاوش قرارگرفته و مزایای این روش بسیار مطلوب گزارش شده &#8204; است. توموگرافی توسط نور یک روش غیرمخرب، سریع، آسان و ارزان است که طی آن ژل معادل توسط نور تابش &#8204; دهی می&#8204;شود و درادامه اطلاعات اپتیکی نسبت به زاویۀ چرخش ژل در معرض تابش، آنطرف توسط CCD دریافت&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;می &#8204; گردد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;این اطلاعات ثبت می &#8204; شود و توسط رایانه تحلیل می&amp;shy;گردد. با درنظرگرفتن درجۀ زاویۀ چرخشی ژل در معرض پرتو و جمع &#8204; آوری اطلاعات اپتیکی ناشی از هر 360 درجه یک کانتور سه &#8204; بُعدی براساس روش مدل &#8204; سازی مبتنی بر FBP ( Filtered Back Projection ) به &#8204; دست می&#8204;&amp;shy;آید. با افزایش تصاویر گرفته &#8204; شده از هر مقطع، تحت عنوان Project ، به &#8204; ازای زوایای عکسبرداری، دقت افزایش می&amp;shy;یابد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری: &lt;/strong&gt;تحقیقات قبلی برروی بهبود کیفیت پرتوی ناشی از منبع نور و بهینه&#8204;سازی چیدمان اپتیکی چندان تمرکزی نداشته&amp;shy;&#8204;اند. این موارد اهداف مقالۀ حاضر را شامل می&amp;shy;گردد. جایگزینی منبع نوری جدید نسبت به منابع نوری متداول، بهینه&#8204;سازی چیدمان اپتیکی و بالابردن کارآیی و حفظ دقت دستگاه از آن جمله&#8204;&amp;shy;اند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Background:&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;In this study, it is proposed a new optical setup for optimizing laser CT scanner -which is used for tissue equivalent gel dosimetry.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Material &amp; Methods:&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; The procedure is based on using a laser diode as a light source and 3 consecutive optical setups to optimize the laser beam in order to reading tissue equivalent gel precisely. To date, magnetic resonance imaging (MRI) has been most extensively used for the evaluation of absorbed dose distributions in gel dosimeters. However, due to the practical problems of availability, cost and artifacts, optical scanning of gel has been used by several researchers as an accurate and practical alternative to MRI; the potential of optical CT method has been explored experimentally and the potential benefits are greatly desirable. Tomography by light is a non-destructive, fast, simple and cheap method in which the tissue equivalent gel is illuminated by light and the optical information is received by a CCD camera on the other side with respect to the rotation angle of the gel.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; The optical information is recorded and analyzed via a computer. Considering gel rotation degree and gathering the optical information from all 360&lt;sup&gt;o&lt;/sup&gt;, a 3-dimensional contour is obtained by programming based on FBP (Filtered Back Projection) method. Images taken from each section are called &amp;quot;projection&amp;quot;. Thus, increasing the number of projects in each distinct angle will enhance the precision.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:normal&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Conclusion:&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt; The previous studies are lacking from attending to improve the light source and optical setup; the proposed optical setup in this paper shows improvements on output profile and consequently taken 3D images enhancing the accuracy.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>دوزیمتری ژل معادل بافت, اسکن CT اپتیکی, توموگرافی, FBP</keyword_fa>
	<keyword>tissue equivalent gel dosimetry, Optical CT scan, Tomography, FBP</keyword>
	<start_page>16</start_page>
	<end_page>21</end_page>
	<web_url>http://icml.ir/browse.php?a_code=A-10-6-131&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مرتضی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عبداللهی شریف</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.abdolahisharif@ee.uut.ac.ir</email>
	<code>1050031947532846004882</code>
	<orcid>1050031947532846004882</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه مهندسی برق، دانشگاه صنعتی ارومیه، ارومیه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>کیوان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اصحابی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004883</code>
	<orcid>1050031947532846004883</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دپارتمان علوم کاربردی، دانشگاه صنعتی مالک اشتر، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
