<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Advances in Skin, Wound and Tissue Repair</title>
<title_fa>Advances in Skin, Wound and Tissue Repair</title_fa>
<short_title>ASWTR</short_title>
<subject>Medical Sciences</subject>
<web_url>http://icml.ir</web_url>
<journal_hbi_system_id>105</journal_hbi_system_id>
<journal_hbi_system_user>journal105</journal_hbi_system_user>
<journal_id_issn>1735-3319</journal_id_issn>
<journal_id_issn_online></journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/aswtr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2011</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر پلتفرم سوییچینگ بر ایمپلنت لیزرلاک بر روی تنش های وارد بر استخوان کرستال به روش آنالیز المان محدود</title_fa>
	<title>Evaluation of Platform Switched Laser-Lok implant on the stress distribution of crestal boneby Finite Element Analysis</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;زمینه و هدف: &lt;/strong&gt;ما در این تحقیق با روش آنالیز المان محدود به بررسی تاثیرطراحیپلتفرمسوئیچینگ روی ایمپلنت Laser-Lok بر روی تنش های وارد بر استخوان کرستال در ناحیه فصل مشترک استخوان با کولار ایمپلنت Laser-Lok می پردازیم و نتایج را با نمونه شاهد مقایسه می نماییم تا مشخص گردد که طراحی پلتفرم&#8204;سوئیچینگ روی ایمپلنت Laser-Lok چه تاثیری بر روی میزان تنش&#8204;های وارد بر استخوان کرستال خواهد گذاشت.&lt;br&gt;
&lt;strong&gt;روش بررسی: &lt;/strong&gt;برای انجام آنالیز المان محدود در ابتدا مدل سه بعدی ایمپلنت اصلی (ایمپلنت Laser-Lok دارای پلتفرم سوئیچینگ) و نمونه شاهد&lt;a name=&quot;_ftnref1&quot;&gt;&lt;sup&gt; &lt;sup&gt;&lt;u&gt;[1]&lt;/u&gt; &lt;/sup&gt;&lt;/sup&gt;&lt;/a&gt;(ایمپلنت Laser-Lok با اباتمنت هم سایز) و همچنین مدل سه بعدی استخوان فک پایین (مندیبل) را تهیه می نماییم. سپس هر دو ایمپلنت را بطور جداگانه با استخوان مندیبل در ناحیه پره مولر و البته با در نظر گرفتن شرایط مرزی مناسب مونتاژ می کنیم. لازم به ذکر است که ایمپلنت شاهداز همه نظر مشابه ایمپلنت اصلی بوده و تنها در سایز اباتمنت متفاوت اند. پس از مش بندی و در نظر گرفتن المان های مورد نظر با توجه به نیروهای وارد بر دندان در حین جویدن و در نظر گرفتن شرایط طبیعی، نیروی 100 نیوتنی را در دو حالت محوری&lt;a name=&quot;_ftnref2&quot;&gt;&lt;sup&gt; &lt;sup&gt;&lt;u&gt;[2]&lt;/u&gt; &lt;/sup&gt;&lt;/sup&gt;&lt;/a&gt;(صفر درجه) و مایل&lt;a name=&quot;_ftnref3&quot;&gt;&lt;sup&gt; &lt;sup&gt;&lt;u&gt;[3]&lt;/u&gt; &lt;/sup&gt;&lt;/sup&gt;&lt;/a&gt;با دو زاویه 15 و 45 درجه به مرکز اباتمنت هر دو ایمپلنت اصلی و شاهد در شرایط کاملا یکسان وارد می کنیم.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt; بطور کلی در اکثر حالات ایمپلنت اصلی نسبت به نمونه شاهد برتر نشان داد و تنش کمتری را به استخوان کرستال اطرافش وارد کرد.نتایج بدست آمده نشان می دهند که طراحی پلتفرم سوئیچینگ نه تنها از مزیت های فیکسچر Laser-Lok در کاهش تنش های برشی و کاهش تحلیل استخوان نمی کاهد بلکه تمرکز تنش در نقاط بحرانی بالایی استخوان کرستال را کاهش داده و تنش ها را به نقاط پایین تر فصل مشترک استخوان کرستال با کولار منتقل می کند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; برای جلوگیری از تحلیل استخوان کرستال فقط کاهش تنش برشی کافی نبوده و حذف عامل بیولوژیکی نیز باید مد نظر قرار گیرد. لذا ایده پلتفرم سوئیچینگ مطرح گردید که می توان با ایجاد پلتفرم در سطح مشترک اباتمنت و فیکسچر از پاشش مایع میان بافتی به بافت های اطراف جلوگیری نموده و از نظر بیولوژیکی مفید می باشد. نتایج کلی حاکی از آن است که ایمپلنت Laser-Lok دارای پلتفرم سوئیچینگ نه تنها تمام مزایای ایمپلنت شاهد را مبنی بر کاهش تنش برشی در فصل مشترک استخوان کرستال و کولار پوشش می دهد بلکه با حذف عامل بیولوژیکی تحلیل استخوان کرستال، مزایای خود را دارد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;hr size=&quot;1&quot; width=&quot;33%&quot; &gt;&lt;p&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Background:&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt; This research analyzes the effect of platform switching design of Laser-Lok implants on the stress distribution in crestal bone of the Laser-Lok implant collar and its surrounding bone interface through Finite Element Analysis (FEA). The results are compared with control implant to show the effect of Laser-Lok implants platform switching design on the stress distribution in crestal bone. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Material and Methods:&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;nbsp; Three-dimensional modeles of the Laser-Lok implant with platform switching, the control implant (a Laser-Lok implant with same size abutment), and the mandible bone is generated for the FEA. Each implant is assembled on the mandible bone in pre-molar considering the proper boundary condition. It should be mentioned that the control implant is similar in all features to the independent implant (LL) except from the size of abutment. After meshing and considering the proper elements regarding the mastication forces and normal condition, a 100N of axial and oblique loading with angles of&amp;nbsp; 15 and 45 angle is applied to the centre of the abutments of both Independent Laser-Lok implant and control implant on same condition.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;font-family:Arial,sans-serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;nbsp; Under different loading conditions the independent implant has shown better results and lower stress distribution on surrounding crestal bone, comparing with control implant. Results demonstrate&amp;nbsp; that the platform switching design will not only ignore the Laser-Lok fixture advantage of reducing the shear forces and bone loss but also will reduce stress concentration on the critical points of upper parts of the crestal bone. Hence transferring the stress distribution to the lower parts of the crestal bone-collar interface. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt; It should be considered that only reducing the shear forces is not enough to decrease crestal bone loss. In this regard, excluding the biological factors should also be considered. Therefore, the platform switching design is proposed as a way to inhibit the interstitial fluid flow to surrounding tissues by creating a platform on the abutment-fixture interface and it is a biological advantages. Total results indicate&amp;nbsp; that Laser-Lok implant with platform switching has not only all the advantages of control implant in reducing the shear forces on crestal bone-collar interface but also has its own advantage of reducing the crestal bone loss by eliminating&amp;nbsp; the biological factor.&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa>پلتفرم سوییچنگ, ایمپلنت Laser-Lok, آنالیز المان محدود(FEA), تحلیل استخوان کرستال, توزیع تنش, سطح ایمپلنت</keyword_fa>
	<keyword>Platform Switching, Laser-Lok Implant, Finite Element Analysis (FEA), Crestal bone loss, Stress distribution, Implant surface</keyword>
	<start_page>35</start_page>
	<end_page>41</end_page>
	<web_url>http://icml.ir/browse.php?a_code=A-10-6-107&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خندانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004826</code>
	<orcid>1050031947532846004826</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده مهندسی پزشکی دانشگاه آزاد اسلامی واحد علوم و تحقیقات</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>الهیار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004827</code>
	<orcid>1050031947532846004827</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابیانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004828</code>
	<orcid>1050031947532846004828</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده مهندسی پزشکی دانشگاه آزاد اسلامی واحد علوم و تحقیقات</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>کاوه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیدان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kseyedan@hotmail.com</email>
	<code>1050031947532846004829</code>
	<orcid>1050031947532846004829</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رنگی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1050031947532846004830</code>
	<orcid>1050031947532846004830</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده مهندسی پزشکی دانشگاه آزاد اسلامی واحد علوم و تحقیقات</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
